Logo iCompetent
En présentiel · Avec un formateurElectrical EngineeringExpertCertificat

Electrical Protection and Relays

Protective relaying for industrial power systems. Covers fault types and fault level, instrument transformers, overcurrent and earth fault grading, differential and distance principles, ANSI device functions, and the testing and settings management that keeps protection trustworthy.

Modules
8
Participants max.
20
Langue
EN

Ce qu'elle couvre habituellement

  1. 1

    Protection as an Engineered System

    • Zones, Overlap and Backup Philosophy
    • System Earthing and Its Effect on Protection
    • Symmetrical Components for the Protection Engineer
    • Fault Calculations for Protection Design
    • The Protection Philosophy and Design Documents
  2. 2

    Faults and Measurement

    • Fault Types and Fault Level
    • Instrument Transformers
    • Dimensioning Protection CTs
    • CT Saturation in Practice
    • VT Connections and Supervision
  3. 3

    Protection Principles

    • Overcurrent, Earth Fault and Grading
    • Unit Protection and Device Functions
    • Designing an Overcurrent Grading Study
    • Directional Overcurrent and Earth Fault Protection
    • Transformer Differential and Restricted Earth Fault in Depth
  4. 4

    Protecting Plant Items

    • Motor Protection Design
    • Generator Protection Design
    • Transformer Protection Beyond Differential
    • Busbar Protection and Arc Detection
    • Feeder and Cable Protection Choices
    • Protection with Drives and Inverter-Based Sources
  5. 5

    Speed, Arc Flash and Dependability

    • Clearing Time and Arc Flash Incident Energy
    • Fast Schemes and Their Trade-offs
    • Breaker Failure Protection Design
    • Trip Circuits, Lockouts and DC Supplies
    • Intertripping and Teleprotection
  6. 6

    Settings, Testing and Management

    • Protection Testing
    • Settings Management and Fault Investigation
    • Commissioning a Protection Scheme
    • Reading Disturbance Records
    • Cyber Security and Firmware Management for Relays
  7. 7

    System Protection and Digital Schemes

    • Under-Frequency Load Shedding
    • Loss of Mains and Islanding Protection
    • Adaptive Protection and Setting Groups
    • Protection over IEC 61850
    • Testing and Isolating Digital Protection Schemes
  8. 8

    Judgement in Practice: Cases and Review

    • Case Study: Protection Review for a Plant Expansion
    • Case Study: An Unwanted Differential Trip on Energisation
    • Case Study: A Fault That Was Not Cleared
    • Case Study: Healthy Feeders Tripping on an Earth Fault
    • Defending a Design When Requirements Conflict
    • Course Review and Next Steps in Protection

Cette page décrit ce que la formation couvre habituellement. Chaque prestataire de formation peut modifier le contenu, la durée et l'ordre pour s'adapter au groupe. Confirmez le contenu final avec le prestataire de formation avant de réserver.

Code
Type
En présentiel
Modules
8
Niveau de compétence
Expert
Langue
EN
Participants max.
20
Certificat
Oui
Évaluation
Non

Vous préférez apprendre à votre rythme ?

Le même sujet en cours en ligne, à commencer dès aujourd'hui.

Autres cours : Génie électrique

Autres cours avec un formateur dans le même domaine.

Avis

Ce que les apprenants disent de Electrical Protection and Relays.

Pas encore d'avis

Soyez la première personne à dire ce que vous avez pensé de Electrical Protection and Relays.

Connectez-vous pour en rédiger un. Nous vérifions chaque avis avant de l'afficher.

Réserver

Est-ce ce que vous cherchiez ?

Contactez notre équipe pour vérifier la disponibilité du cours et des places dans le lieu de votre choix

Réserver
Image for the book now section

Obtenir un devis